← All recalls

Recall to Repair: Whitco Company LP Stadium Light Poles Can Fall Over, Posing Risk of Serious Injury and Death

CPSC · 10295 · published 2010-07-06

CPSC campaign 10295

Hazard

Collapse

Remedy

To reduce the risk of injury, Whitco Co. LP light poles should be inspected by an engineer or a Level II non-destructive testing technician immediately to identify cracking at or near the weld connecting the pole to the base plate flange. A visual examination with the naked eye or with a magnifier will not determine the extent of any cracking. Non-destructive techniques such as magnetic particle inspection, dye penetrant, or ultrasonic inspection techniques are recommended. If any cracking or fracturing is found, immediately have the affected poles repaired or replaced by a qualified professional. A design analysis to assess the stresses placed on the pole is also recommended. CPSC recommends that all outdoor steel stadium light poles be routinely inspected by a professional. As the manufacturer has become bankrupt, individual owners of the poles must arrange for inspection.

The text above is quoted verbatim from the CPSC record. Confirm the affected units and the remedy with the manufacturer or CPSC. Recall data may be incomplete, delayed, or superseded.

Own something like this?

Track your items and we’ll tell you the moment a recall covers one — free, forever.

Track an item like this

Affected products

Whitco Company LP, of Fort Worth, Texas (which is out of business)

Whitco Company LP poles 70 feet tall or higher

Brands in this recall